Main Cable types and names: ¡ú(Type Table
| 1 | 2
| 3 | 4
)
¡¡¡¡¡ô HYA-----copper conductor,solid polyolefin insulated, aluminium
and Plastic composite sheathed, local communication cable.
¡¡¡¡¡ô HYAT-----copper conductor, solid polyolefin insulated, jelly
filled, aluminium and plastic composite sheathed, local communication
cable.
¡¡¡¡¡ô HYPA-----copper conductor, foam skin polyolefin insulated,
aluminium and plastic composite sheathed, local communication
cable.
¡¡¡¡¡ô HYPAT-----copper conductor, foam skin plolyolefin insulated,
jelly filleg, aluminium and plastic composite sheathed,local communication
cable.
¡¡¡¡¡ô HYAC-----copper conductor, solid polyolefin insulated, aluminium
and plastic composite sheathed, selfsupporting local communication
cable.
¡¡¡¡¡ô HYA53-----copper conductor, solid polyolefin insulated, aluminium
and plastic copmosite sheathed, single steel tape armoured, outer
polythene sheathed local communication cable.
¡¡¡¡¡ô HYAT53-----copper conductor, solid polyolefin insulated, jelly
filled, aluminium and plastic composite sheathed, single steel
tape armoured, outer polythene sheathed, local communication cable.
¡¡¡¡¡ô HYPA53-----copper conductor, foam skin polyolefin insulated,
aluminium and plasyic composite sheathed,single steel tape armoured,
outer polythene sheathed, local communication cable.
¡¡¡¡¡ô HYPAT53-----copper conductor, foam skin polyolefin insulated,jelly
filled, aluminium and plastic composite sheathed, single steel
tape armoured, outer polythene sheathed, local communication cable.
APPLICATION:
HYA, HYAT, HYAC, HYPAT, HYPA and HYA53, HYAT53, HYPA53, HYPAT53
cables are Telephone cables designed for telephone exchange area
and trunk line. HYA,HYAT,HYPA and HYPAT can mainly be used in
duct, sometimes overhead with messanger needed. HYAC can only
be Used overhead with nomessenger. HYA53, HYAT53, HYPA, HYPAT53
cables mechnical Strength and anti-corrosive capacity, can be
used any way, especially direct buried in rook area. The operating
temperature are all -30¡æ¡«£«600¡æ.
STRUCTURE:
1. Conductor: annealed bare copper wires, wire diameters: 0.32,
0.4,0.5,0.6,0.7,0.8,0.9mm.
2. Insulation material: High density polythene or polypropylene.
Insulation of type HYPA, HYPAT, HYPA53 and HYPAT53 cables is divided
into two parts inside part is made of foam polythene, outside
part is made of solid polythene. Insulated wires are marked with
colors according to the full colorcode standard.
3. Insulated parirs: the insulated conductors are twisted into
pairs with varying lay lengths so as to reduce crosstalk to the
least degree. Special chromatic combinations are applied for the
indentification of the pairs.
4. Core structure: 25 pairs form a unit. Cables having more than
25 pairs are assembled in units. Each unit is lapped up with bindings
of specified colors for the convenience of identification. An
extra 1% of spare pairs, but not exceeding 6 pairs, (for cable
with §¶0.32mm conductor diameter, max 10 pairs )are attached to
the cable of 100 pairs or more. The interstices inside HYAT and
HYPAT cable cores are filled with jelly.
5. Core wrapping: Nonhygroscopic tapes are used to wrap up the
core.
6. AL / plastic composite sheath.
(1) shield: A plastic coated aluminium tape of 0.3mm thick is
applied longitudinally over the core wrap with two edge over lapped
and seam sealed. For the cable of more than 400 pairs, the longitudlinal
applied tape is corrugated.
(2) Sheath:low density black polythene.
7. Cable with additional mechanical protection layer(53 type)
(1) basic cable: mechanical protection layer can be added to all
basic cable types HYA,HYAT,HYPA,HYPAT.
(2) Mechanical protection layer: corrugated steel/plastic composite
tape of 0.25mm thick is applied longitudinally over the basic
cable with two edges overlapped.
(3) Outer sheath:low density black polythene.
8. identification and length mark:on the surface of the calbe,
at intervals fo 1 metre, are printed the perpetual marks, such
as type, specifications, manufacturer, trade mark, year of manufacturer
and sequentially unmbered length marks.
|